Courses are offered at your facility (with your
instrumentation). All courses are "hands-on" and teach practical instrument
knowledge in a number of different areas. Course prices are based on actual location,
number of individuals and topics covered. Custom courses designed to suit your exact needs
can also be quoted. Please email/phone us for more information. Some of our more popular
courses include :
HP / Agilent ChemStation (OpenLAB) Operation For HPLC
- Introductory overview of software and hardware
features (includes review of the most popular Hardware modules (either a 1050, 1090, 1100,
1200, 1260 or 1290-Series), detailed instrument set-up tips, degasser operation, method
creation & editing, sequences, report styles, simple automation, calibration tables,
spectral features, peak purity, and detailed maintenance procedures.
|
2
Days (CS-2001) |
HP / Agilent ChemStation Operation For HPLC
(Advanced)
- Overview of special features including; Optimization
and operation of your HPLC and computer data system, automating calibration procedures,
automating methods, customization of standard reports, use of export file report feature
and use of diagnostic tests.
|
1 Day (CS-2002) |
HP / Agilent ChemStation Operation For HPLC (Mini-Course)
- A one day version of our CS-2001 course. An
introductory overview of the hardware features of either an HP 1050, 1090, 1100,
1200, 1260 or 1290-Series system, method creation, method editing, naming, sequence
parameters, report styles, DAD spectral features (i.e. bandwidth, reference, sample
rate) and basic maintenance/service procedures under ChemStation software.
|
1 Day (CS-2003) |
HP / Agilent LC-MSD Operation
- Overview of how to actually use HP’s newest
bench top LC-MS system to acquire accurate data. Includes hints and tips on the typical
set-up and operation with an electrospray source (ESI) to determine the correct molecular
weight of pharmaceutical compounds. Topics covered include; proper HPLC operation and
column selection for use in LC-MS, instrument calibration, choosing correct voltage ramps
and lens settings for different compounds, solvent choices, forming adducts, positive and
negative modes, use of post column doping, and interpretation of results.
|
1 or 2 Days (CS-2004) |
HP
1050/1090/1100/1200, 1260 or 1290 Diode Array Optimization {HP ChemStation Topics}
- Use of diode array detector in method development.
Includes overview of ChemStation set-up and optimization for specific applications and
sample types. Advanced Peak Purity (The single most misunderstood function), Use of
reference wavelengths, proper flow cell, slit and wavelength selection as well as library
searching are covered. "One of the most practical and useful courses you will ever
take".
|
1 Day (CS-2006) |
ChemStation
Quantification & Calibration {HP ChemStation Topics}
- Common procedures used to perform HPLC quantitative
analysis using the HP ChemStation software. Both the importance of proper method
development, operation, automation, when and how to update the calibration table data as
well as custom reporting topics are covered.
|
1 Day (CS-2008) |
Automated HPLC Method Development {HP
ChemStation Topics}
- Strategies to improve your method development
procedures using either the HP 1050, 1090, 1100, 1200, 1260 or 1290-Series HPLC and/or
LC-MSD systems for "after hours" or unattended operation. Various instrument
add-ons as well as optimization of your existing hardware and software will be discussed
that can both improve your daily sample throughput as well as increase the quality of your
data.
|
1 Day (CS-2010) |
Chiral
HPLC Method Development Strategies
- Unbiased information (we do not sell columns
!) that will help you develop high quality chiral HPLC methods on any brand of HPLC
system. Column, mobile phase selection and automation will be discussed. We are experts in
the chiral HPLC method development field.
|
1 Day (CS-2014) |
General
HPLC Method Development Strategies
- Unbiased information (we do not sell columns
!) that will help you develop high quality Reversed and Normal phase HPLC methods on your
HPLC system. Column, mobile phase selection and automation will be discussed.
|
1 Day (CS-2012) |
HP
1050 Service and Maintenance
- Instructions and demonstrations as to how to repair
and maintain the HP 1050 HPLC modules. Includes all common maintenance procedures such as
piston, piston seal, needle, needle seat, rotor seal, flow cell cleaning, lamp testing and
replacement, custom diagnostic tests and troubleshooting procedures to keep your
instrument operating at it’s peak performance.
|
1 Day (CS-2050-3) |
HP
1090 Service and Maintenance
- Instructions and demonstrations as to how to repair
and maintain the research grade HP 1090L or 1090M HPLC system. Includes all common
maintenance procedures such as piston, piston seal, needle, needle seat, rotor seal, flow
cell cleaning and repair, lamp testing and replacement, optical switch replacement, wash
system, rotary valve, metering pump, HPIB configuration, installation of injector and/or
pump upgrades, custom diagnostic tests and troubleshooting procedures specific to DR-5 and
PV-5 systems to keep your instrument operating at it’s peak performance.
|
1 or 2 Days (CS-2090-3) |
HP
/ Agilent 1100 & 1200, 1260 or 1290 Service and Maintenance
- Instructions and demonstrations as to how to repair
and maintain one of the HP/Agilent Technologies 1100, 1200, 1260 or 1290-Series HPLC
system. Includes common maintenance procedures such as piston, piston seal, needle, needle
seat, rotor seal, flow cell cleaning and repair, lamp testing and replacement, custom
diagnostic tests and troubleshooting procedures to keep your instrument operating at
it’s peak performance. CLASS COVERS ONE Version. SELECT ONE INSTRUMENT MODEL for class (e.g. 1100-series).
|
1 Day
Each Agilent 1100/1200-Series
(CS-2100-3);
Agilent 1200/1260-Series (CS-2260-3);
Agilent 1290-Series (CS-2290-3) |

Chiralizer™ Services, LLC, USA
© Copyright 1993 to 2023, Chiralizer™
Services, L.L.C. All Rights Reserved.
E-mail : Sales@LC-MS.com Phone :
1-919-241-4858.
|