The CS3010, Column Swapper (PHOTO) is a multipurpose instrument designed to either increase sample
throughput or automate sample clean-up. Same unit can be used for either application.
*Typical application is for Alternating Column Regeneration (ACR).
HIGH THROUGHPUT SAMPLE ANALYSIS :
Instrument allows simultaneous analysis of one sample on one HPLC column while a second,
identical column is flushed (or backflushed) and equilibrated off-line. At the end of the
first analysis the columns are 'swapped'. The original analysis is then performed on the
previously-flushed and equilibrated column while the original column is flushed and
equilibrated off-line. This process is known as 'ACR'. A huge time saver ! Cut repetitive
analysis times in half.
Product provides a visual indication of which of
the two columns is being used for the current analysis as well as a chart mark output, for
GLP documentation, each time the units swaps the columns. Requires two pumps and one
available contact closure for programming the system. Can be connected to most
manufacturers HPLC systems.
Note : A special custom installed version is
available for customers of Agilent Technologies (formerly Hewlett-Packard Company)
Thermostated Column Compartment (Agilent's Model G1316A Block Heater with option #057). We
can custom install our special 2-Position, 10-Port valve inside of their column oven for a
nice custom look at a greatly reduced price, plus you can still use your block heater to
control the temperature of the two columns. You may then control the Alternating Column
Regeneration process directly through your ChemStation software! *Agilent refers to this
as a Model # G1157A. Please inquire about this special product (Model CS3010-S) by
phoning us directly. SEE PHOTO.
OR
RAPID
SAMPLE PREP & ANALYSIS : Automate sample clean-up to remove plasma and proteins prior
to introduction into either MS or UV detector using one HPLC column and two pumps. One
pump is used for sample clean-up while the other pump is used for the actual analysis. The
solvent flow path can be flushed down off-line during the actual sample analysis period.
Easily and inexpensively automate your
sample prep tasks with this one device. Requires two computer controlled pumps (gradient
capable preferred) and one available contact closure for programming the sample clean-up
step. Can be connected to most manufacturers HPLC or LC-MS systems.
List Price $ 3,250 (US $) *