Courses are offered at your facility (with your
instrumentation). All courses are "hands-on" and teach practical instrument
knowledge in a number of different areas. Chiralizer is not affiliated with Agilent
Technologies so you will receive completely unbiased, expert information, hints and tips
to allow you to instantly upgrade your chromatography skills. Course prices are based on
actual location, number of individuals and topics covered. Custom courses designed to suit
your exact needs can also be quoted. Please email/phone us for more information. Some of
our more popular courses include :
HP / Agilent ChemStation Operation For HPLC
- Introductory overview of software and hardware
features (includes review of the most popular Hardware modules (You select one model #:
1050, 1090, 1100, 1200, 1260 or 1290-Series), detailed instrument set-up tips, method
creation, sequences, report styles, simple automation, calibration tables, spectral
features, peak purity, and detailed maintenance procedures.
|
2
Days (CS-2001) |
HP / Agilent ChemStation Operation For HPLC
(Advanced)
- Overview of special features including; Optimization
and operation of your HPLC and computer data system, automating calibration procedures,
automating methods, customization of standard reports, use of export file report feature
and use of diagnostic tests.
|
1 Day (CS-2002) |
HP / Agilent ChemStation Operation For HPLC (Mini-Course)
- A one day version of our CS-2001 course. An
introductory overview of the hardware features for a single instrument model (HP
1050, 1090, 1100, 1200, 1260 or 1290-Series system), method creation, method
editing, naming, sequence parameters, report styles, DAD spectral features (i.e.
bandwidth, reference, sample rate) and basic maintenance/service procedures under
ChemStation software.
|
1 Day (CS-2003) |
HP / Agilent LC-MSD Operation
- Overview
of how to actually use HP’s newest bench top LC-MS system to acquire
accurate data. Includes hints and tips on the typical set-up and
operation with an electrospray source (ESI) to determine the correct
molecular weight of pharmaceutical compounds. Topics covered include;
proper HPLC operation and column selection for use in LC-MS, instrument
calibration, choosing correct voltage ramps and lens settings for
different compounds, solvent choices, forming adducts, positive and
negative modes, use of post column doping, and interpretation of
results. This is a 'hands-on" advanced client level course for
experienced users only.
|
1 or 2 Days (CS-2004) |
HP
1050/1090/1100/1200, 1260 or 1290 Diode Array Optimization {HP ChemStation Topics}
- Use of diode array detector in method development
for a single instrument model (HP 1050, 1090, 1100, 1200, 1260 or 1290-Series system).
Includes overview of ChemStation set-up and optimization for specific applications and
sample types. Advanced Peak Purity (The single most misunderstood function), Use of
reference wavelengths, proper flow cell, slit and wavelength selection as well as library
searching are covered. "One of the most practical and useful courses you will ever
take". This is a 'hands-on" advanced level course for experienced users only.
|
1 Day (CS-2006) |
ChemStation
Quantification & Calibration {HP ChemStation Topics}
- Common procedures used to perform HPLC quantitative
analysis using the HP ChemStation software. Both the importance of proper method
development, operation, automation, when and how to update the calibration table data as
well as custom reporting topics are covered.
|
1 Day (CS-2008) |
Automated HPLC Method Development {HP
ChemStation Topics}
- Strategies to improve your method development
procedures using one instrument model (HP 1050, 1090, 1100, 1200, 1260 or 1290-Series
HPLC) and/or LC-MSD systems for "after hours" or unattended operation. Various
instrument add-ons as well as optimization of your existing hardware and software will be
discussed that can both improve your daily sample throughput as well as increase the
quality of your data.
|
1 Day (CS-2010) |
Chiral
HPLC Method Development Strategies
- Unbiased information (we do not sell columns
!) that will help you develop high quality chiral HPLC methods on any brand of HPLC
system. Column, mobile phase selection and automation will be discussed. We are experts in
the chiral HPLC method development field.
|
1 Day (CS-2014) |
General
HPLC Method Development Strategies
- Unbiased information (we do not sell columns
!) that will help you develop high quality Reversed and/or Normal phase HPLC methods on
your HPLC system. Column, mobile phase selection and automation will be discussed.
|
1 Day (CS-2012) |
HP
1050 Service and Maintenance
- Instructions and demonstrations as to how to repair
and maintain the HP 1050 HPLC modules. Includes all common maintenance procedures such as
piston, piston seal, needle, needle seat, rotor seal, flow cell cleaning, lamp testing and
replacement, custom diagnostic tests and troubleshooting procedures to keep your
instrument operating at it’s peak performance.
|
1 Day (CS-2050-3) |
HP
1090 Service and Maintenance
- Instructions
and demonstrations as to how to repair and maintain the research grade
HP 1090L or 1090M HPLC system. Includes all common maintenance
procedures such as piston, piston seal, needle, needle seat, rotor
seal, flow cell cleaning and repair, lamp testing and replacement,
optical switch replacement, wash system, rotary valve, metering pump,
HPIB configuration, installation of injector and/or pump upgrades,
custom diagnostic tests and troubleshooting procedures specific to DR-5
and PV-5 systems to keep your instrument operating at it’s peak
performance. This is a 'hands-on" advanced client level course for
experienced users only.
|
1 or 2 Days (CS-2090-3) |
HP
/ Agilent 1100 & 1200, 1260 or 1290 Service and Maintenance
- Instructions
and demonstrations in how to repair and maintain one of the HP/Agilent
Technologies 1100, 1200, 1260 or 1290-Series HPLC systems (select one
model only). Includes common maintenance procedures such as piston,
piston seal, needle, needle seat, rotor seal, flow cell cleaning and
repair, lamp testing and replacement, custom diagnostic tests and
troubleshooting procedures to keep your instrument operating at it’s
peak performance. This is a 'hands-on" advanced client level course for
experienced users only. CLASS COVERS ONE Version. SELECT ONE INSTRUMENT MODEL for class (e.g. 1100-series).
|
1 Day
Each Agilent 1100/1200-Series
(CS-2100-3);
Agilent 1200/1260-Series (CS-2260-3);
Agilent 1290-Series (CS-2290-3) |
Chiralizer™ Services, LLC, USA
© Copyright 1993 to 2023, Chiralizer™
Services, L.L.C. All Rights Reserved.
E-mail : Sales@LC-MS.com Phone :
1-919-241-4858.
|